PERFORMANCE
|
ENGLISH |
SI |
|
Measurement Range
|
0.0 to 2 in/sec pk
|
|
|
|
|
Output
|
4-20 mA
|
|
|
|
|
Frequency Range (±10 %)
|
180 to 60,000 cpm
|
|
|
|
|
Broadband Resolution
|
0.01 in/sec pk
|
|
|
|
|
Non-Linearity
|
±1 %
|
|
|
ENVIRONMENTAL
|
|
Temperature Range
|
-40 to 185 °F
|
|
|
ELECTRICAL
|
|
Excitation Voltage
|
12 to 30 VDC
|
|
|
|
|
Settling Time (within 2% of value)
|
<15 sec
|
|
|
|
|
Electrical Isolation (Case)
|
>108 ohm
|
|
|
PHYSICAL
|
|
Size - Hex
|
1.0 in
|
|
|
|
|
Size - Height
|
2.6 in
|
|
|
|
|
Weight
|
4.7 oz
|
|
|
|
|
Mounting Thread
|
1/4-28 UNF
|
|
|
|
|
Mounting Torque
|
3 to 5 ft-lb
|
|
|
|
|
Sensing Element
|
Ceramic
|
|
|
|
|
Sensing Geometry
|
Shear
|
|
|
|
|
Housing Material
|
Stainless Steel
|
|
|
|
|
Sealing
|
Welded Hermetic
|
|
|
|
|
Electrical Connector
|
2-Pin MIL-C-5015
|
|
|
|
|
Electrical Connection Position
|
Top
|
|
|
|
|
Electrical Connections (Pin A)
|
4-20 mA Pos (+)
|
|
|
|
|
Electrical Connections (Pin B)
|
4-20 mA Neg (-)
|
|
|
SUPPLIED ACCESSORIES:
|
| Model 081A40 Mounting Stud (1) |
| Model ICS-4 NIST-traceable single-axis amplitude response calibration from 0 cpm (0 Hz) to upper 10% frequency for 4 - 20 mA output vibration sensor (1) |
|
OPTIONAL VERSIONS |
| EX - Hazardous Area Approval- contact factory for specific approvals |
|
|
|
Hazardous Area Approval
|
DIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4
|
|
|
Hazardous Area Approval
|
EEx ia IIC T4, -40°C≤Ta≤80°C, II 1 G
|
|
|
Hazardous Area Approval
|
EEx nL IIC T4, -40°C≤Ta≤80°C, II 3 G
|
|
|
Hazardous Area Approval
|
DIV I, CL I, II, III, GRPS A-G, Exia, AExia, IIC T4
|
|
|
|
|
Supplied Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1 (1) replaces Model 081A40
|
| RV - Buffered Analog Signal Output - 100 mV/g (±20%) |
|
|
|
Electrical Connector
|
3-Pin MIL-C-5015
|
|
|
Electrical Connections (Pin A)
|
4-20 mA Pos (+)
|
|
|
Electrical Connections
(Pin B)
|
4-20 mA Neg/Signal Output Neg
|
|
|
Electrical Connections
(Pin C)
|
Signal Output Pos
|
|