The model 683A panel meter can be used with either ICP sensors or 4-20 mA vibration transmitters depending on the options selected. Each display also features two programmable relays with time delays and optional 4-20 mA re-transmit. Below are some of our more popular models but for a full ordering guide click on the pdf brochure at the bottom of the page.
 
 
Choose a Displays & Alarms product below...

  
Indicator/Controller (for use w/ ICP® sensors)
Model 683A101000     
 
Indicator/Controller (for use w/ ICP® sensors) w/retransmit option

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: None
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for 4-20 mA sensors)
Model 683A001000     
 
Indicator/Controller (for use w/ 4 to 20 mA sensors) w/retransmit option

ICP Indicator/ Controller for 4-20 mA loop-powered Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 4 to 20 mA
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Output Signal: 4 to 20 mA
  • Accessories: None
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for ICP® sensors)
Model 683A100000     
 
Indicator/Controller (for use w/ ICP® sensors)

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: None
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for ICP® sensors)
Model 683A100001     
 
Indicator/Controller (for use w/ ICP® sensors) w/NEMA-4X cover

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, NEMA 4X cover. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: NEMA 4X Cover
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for ICP® sensors)
Model 683A101001     
 
Indicator/Controller (for use w/ ICP® sensors) w/retransmit option & NEMA-4X cover

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, NEMA 4X cover, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: NEMA 4X Cover
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for ICP® sensors)
Model 683A101002     
 
Indicator/Controller (for use w/ ICP® sensors) w/retransmit option & metal surround case

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, metal surround case, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: Metal Surround Case
  • Channels: 1
 
More Information
 
 

  
Indicator/Controller (for use w/ ICP® sensors)
Model 683A100003     
 
Indicator/Controller (for use w/ ICP® sensors) w/NEMA-4X cover & metal surround case

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, NEMA 4X cover & metal surround case. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: NEMA 4X Cover & Metal Case
  • Channels: 1
 
More Information
 
 

  
Indicator/Controller (for use w/ ICP® sensors)
Model 683A101003     
 
Indicator/Controller (for use w/ ICP® sensors) w/retransmit option, NEMA-4X cover & metal surround case

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 85- 265 VAC/ 95- 370 VDC powered, dual relays, NEMA 4X cover & metal surround case, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 85-265 VAC/95-370 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: NEMA 4X Cover & Metal Case
  • Channels: 1
 
More Information
 
 

  
Indicator/Controller (for use w/ ICP® sensors)
Model 683A111001     
 
Indicator/Controller (for use w/ ICP® sensors) w/10-27 VDC power input, retransmit option & NEMA-4X cover

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 18-48 VAC/ 10-72 VDC powered, dual relays, NEMA 4X cover, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 18-48 VAC/10-72 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: NEMA 4X Cover
  • Channels: 1
 
More Information
 
 

  
Indicator / Alarm (for ICP® sensors)
Model 683A111002     
 
Indicator/Controller (for use w/ ICP® sensors) w/10-27 VDC power input, retransmit option & metal surround case

ICP Indicator/ Controller for 100 mV/g ICP Sensor, 18-48 VAC/ 10-72 VDC powered, dual relays, metal surround case, 4-20 mA re-transmit. Programmability includes scale factor, offset, decimal point location, set point adjustment, peak and valley view with reset, LED brightness, time delay on relay make or break, HI or LOW set point relay action, relay hysterisis.

  • Input Signal: 100 mV/g (100 mV/(m/s²))
  • Power Required: (Auto Sensing) 18-48 VAC/10-72 VDC
  • Output Signal: 4 to 20 mA
  • Frequency Response: (±3dB) 3 to 10k Hz
  • Accessories: Metal Surround Case
  • Channels: 1
 
More Information
 
 