Sign Up Now
FREE E-Newsletter

Search



ABOUT SSL CERTIFICATES

 

Universal Transmitter w/ICP Power
Model 682A16     
 
ICP Alarm Module

Fully programmable universal transmitter with current output, voltage output, and two relay outputs. Provides ICP excitation for analog 100 mV/g accelerometers. Fully programmable via detachable display (sold separately- Model 070A80 ), and operates from 19.2 to 300 VDC, or 21.5 to 253 VAC power.

 
 
SpecificationsDrawingProduct ManualPicture 
ENVIRONMENTAL ENGLISH SI
Temperature Range (Operating) -04 to 140 °F
-20 to 60 °C
ELECTRICAL
Supply Voltage 19.2 to 300 VDC
19.2 to 300 VDC
Current Consumption ≤ 2.5 W
≤ 2.5 W
Excitation Voltage (delivered to sensor) 23 to 25 VDC
23 to 25 VDC
Constant Current Excitation (delivered to sensor) 3 to 5 mA
3 to 5 mA
PHYSICAL
Size - Width 0.93 in
23.5 mm
Size - Height 4.29 in
109 mm
Size - Depth 4.09 in
104 mm
Weight 6.00 oz
170 gm

All specifications are at room temperature unless otherwise specified.


View Spec Sheet: 682A16_NR.pdf
 
 

Model 682A06 - Universal Transmitter
The Universal Transmitter features a removeable LCD display, dual relays with time delays and 4-20 mA re-transmit. A cost-effective method of overall vibration monitoring it can also be used in conjunction with non-IMI products such as RTD's.