Sign Up Now
FREE E-Newsletter

Search



ABOUT SSL CERTIFICATES

 

Very High Frequency ICP® Accelerometer
Model 621B40     
 
High freq. laboratory ceramic shear ICP® accel, 10 mV/g, 1.6 to 30k Hz, titanium case, top exit, 5-44 conn.
  • Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²))
  • Frequency Range: (±10%) 204 to 1080000 cpm (3.4 to 18000 Hz)
  • Frequency Range: (±3dB) 96 to 1800000 cpm (1.6 to 30000 Hz)
  • Measurement Range: ±500 g (±4905 m/s²)
  • Electrical Connector: 5-44 Coaxial Jack
 
 
SpecificationsDrawingProduct ManualPictureTemperature 
PERFORMANCE ENGLISH SI
Sensitivity (±10 %) 10 mV/g
1.02 mV/(m/s2) [1]
Measurement Range ±500 g
±4,905 m/s²
Frequency Range (±10 %) 204 to 1,080,000 cpm
3.4 to 18,000 Hz [2][4]
Frequency Range (±3 dB) 96 to 1,800,000 cpm
1.6 to 30,000 Hz [2][4]
Resonant Frequency 5,100 kcpm
85 kHz [3][5]
Broadband Resolution (1 to 10,000 Hz) 1.2 mg rms
1,176 µm/sec2 [5]
Non-Linearity ±1 %
±1 % [6]
Transverse Sensitivity ≤ 5 %
≤ 5 %
ENVIRONMENTAL
Overload Limit (Shock) 10,000 g pk
98,100 m/s2 pk
Temperature Range -65 to 250 °F
-54 to 121 °C
Temperature Response See Graph
See Graph [5]
ELECTRICAL
Settling Time (within 1% of bias) ≤ 3.0 sec
≤ 3.0 sec
Discharge Time Constant ≥ 0.1 sec
≥ 0.1 sec
Excitation Voltage 18 to 28 VDC
18 to 28 VDC
Constant Current Excitation 2 to 20 mA
2 to 20 mA
Output Impedance <100 Ohm
<100 Ohm
Output Bias Voltage 8 to 12 VDC
8 to 12 VDC
Spectral Noise (10 Hz) 100 µg/√Hz
980 (µm/sec2)/√Hz [5]
Spectral Noise (100 Hz) 30 µg/√Hz
294 (µm/sec2)/√Hz [5]
Spectral Noise (1 kHz) 10 µg/√Hz
98.1 (µm/sec2)/√Hz [5]
PHYSICAL
Size - Hex 3/8 in
9.6 mm
Size - Height 0.66 in
16.8 mm
Weight 0.10 oz
2.8 gm
Mounting Thread 5-40 Male
M3 x 0.50 Male
Mounting Torque 18 to 20 in-lb
203 to 226 N-cm
Sensing Element Ceramic
Ceramic
Sensing Geometry Shear
Shear
Housing Material Titanium
Titanium
Sealing Welded Hermetic
Welded Hermetic
Electrical Connector 5-44 Coaxial Jack
5-44 Coaxial Jack
Electrical Connection Position Top
Top
SUPPLIED ACCESSORIES:
Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to upper 5% frequency
OPTIONAL VERSIONS
M - Metric Mount

All specifications are at room temperature unless otherwise specified.
NOTES:
[1] Conversion Factor 1g = 9.81 m/s².
[2] Frequency response with adhesive base.
[3] Mounted resonance (nominal) without magnet.
[4] The high frequency tolerance is accurate within ±10% of the specified frequency.
[5] Typical value.
[6] Zero-based, least-squares, straight line method.




View Spec Sheet: 621B40_L.pdf
 
Related Products
Flat Surface Magnet
Flat Surface Magnet
Model 080A157
Very High Frequency ICP® Accelerometer Kit
Very High Frequency ICP® Accelerometer Kit
Model 600A12