High Frequency Industrial ICP® Accelerometer
Model 623C00
High-freq., industrial, ceramic shear ICP® accel, 10 mV/g, 0.8 to 15k Hz, top exit, 2-pin conn.
- Sensitivity: (±5%) 10 mV/g (1.0 mV/(m/s²))
- Frequency Range: (±5%) 144 to 480000 cpm (2.4 to 8000 Hz)
- Frequency Range: (±3dB) 48 to 900000 cpm (0.8 to 15000 Hz)
- Measurement Range: ±500 g (±4905 m/s²)
- Electrical Connector: 2-Pin MIL-C-5015
|
PERFORMANCE
|
ENGLISH |
SI |
|
Sensitivity (±5 %)
|
10 mV/g
|
|
|
|
|
Measurement Range
|
±500 g
|
|
|
|
|
Frequency Range (±5 %)
|
144 to 480,000 cpm
|
|
|
|
|
Frequency Range (±10 %)
|
102 to 600,000 cpm
|
|
|
|
|
Frequency Range (±3 dB)
|
48 to 900,000 cpm
|
|
|
|
|
Resonant Frequency
|
2,400 kcpm
|
|
|
|
|
Broadband Resolution (1 to 10,000 Hz)
|
300 µg
|
|
|
|
|
Non-Linearity
|
±1 %
|
|
|
|
|
Transverse Sensitivity
|
≤ 5 %
|
|
|
ENVIRONMENTAL
|
|
Overload Limit (Shock)
|
5,000 g pk
|
|
|
|
|
Temperature Range
|
-65 to 250 °F
|
|
|
|
|
Temperature Response
|
See Graph
|
|
|
|
|
Enclosure Rating
|
IP68
|
|
|
ELECTRICAL
|
|
Settling Time (within 1% of bias)
|
≤ 3.0 sec
|
|
|
|
|
Discharge Time Constant
|
≥ 0.2 sec
|
|
|
|
|
Excitation Voltage
|
18 to 28 VDC
|
|
|
|
|
Constant Current Excitation
|
2 to 20 mA
|
|
|
|
|
Output Impedance
|
<100 Ohm
|
|
|
|
|
Output Bias Voltage
|
8 to 12 VDC
|
|
|
|
|
Spectral Noise (10 Hz)
|
12 µg/√Hz
|
|
|
|
|
Spectral Noise (100 Hz)
|
4.5 µg/√Hz
|
|
|
|
|
Spectral Noise (1 kHz)
|
2.7 µg/√Hz
|
|
|
|
|
Electrical Protection
|
RFI/ESD
|
|
|
|
|
Electrical Isolation (Case)
|
>108 Ohm
|
|
|
PHYSICAL
|
|
Size - Hex
|
11/16 in
|
|
|
|
|
Size - Height
|
1.97 in
|
|
|
|
|
Weight
|
1.80 oz
|
|
|
|
|
Mounting Thread
|
1/4-28 Female
|
|
|
|
|
Mounting Torque
|
2 to 5 ft-lb
|
|
|
|
|
Sensing Element
|
Ceramic
|
|
|
|
|
Sensing Geometry
|
Shear
|
|
|
|
|
Housing Material
|
Stainless Steel
|
|
|
|
|
Sealing
|
Welded Hermetic
|
|
|
|
|
Electrical Connector
|
2-Pin MIL-C-5015
|
|
|
|
|
Electrical Connection Position
|
Top
|
|
|
SUPPLIED ACCESSORIES:
|
| Model 081A40 Mounting Stud (1) |
| Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to upper 5% frequency |
|
OPTIONAL VERSIONS |
| CS - Canadian Standards Association Approved Intrinsically Safe |
|
|
|
Hazardous Area Approval
|
Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
|
|
|
Hazardous Area Approval
|
Exia IIC T4, AExia IIC, T4
|
|
|
Hazardous Area Approval
|
Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
|
|
| EX - Hazardous Area Approval- contact factory for specific approvals |
|
|
|
Hazardous Area Approval
|
EEx ia IIC T4, -54°C≤Ta≤121°C, II 1 G
|
|
|
|
|
Output Bias Voltage
|
6 to 8 VDC
|
|
|
Excitation Voltage
|
12 to 28 VDC
|
|
|
Measurement Range
|
350 g
|
|
|
|
|
Supplied Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1 (1) replaces Model 081A40
|
All specifications are at room temperature unless otherwise specified.
|
| NOTES: |
| [1] |
1/4-28 has no equivalent in S.I. units. |
| [2] |
Conversion Factor 1g = 9.81 m/s². |
| [3] |
See PCB Declaration of Conformance PS023 or PS061 for details. |
| [4] |
The high frequency tolerance is accurate within ±10% of the specified frequency. |
| [5] |
Typical. |
| [6] |
Zero-based, least-squares, straight line method. |
|
|
|
View Spec Sheet: 623C00_D.pdf
|
|