Very High Temperature ICP® Accelerometer Kit
Model 600A13
High temperature, charge mode accelerometer kit containing a side exit accelerometer, 10 ft integral hard-line cable, and integral charge amplifier
- Sensitivity: (±5%) 100.0 mV/g (10.2 mV/(m/s²))
- Frequency Range: (±5%) 282 to 240000 cpm (4.7 to 4000 Hz)
- Measurement Range: (Peak) ±50 g (±490 m/s²)
- Mounting: Through Holes (3)
- Electrical Connector: 2-Pin MIL-C-5015
|
PERFORMANCE
|
ENGLISH |
SI |
|
Sensitivity (±5 %)
|
100.0 mV/g
|
|
|
|
|
Measurement Range (Peak)
|
±50 g
|
|
|
|
|
Frequency Range (±5 %)
|
282 to 240,000 cpm
|
|
|
|
|
Frequency Range (±10 %)
|
204 to 300,000 cpm
|
|
|
|
|
Resonant Frequency
|
1,380 kcpm
|
|
|
|
|
Broadband Resolution (1 to 10,000 Hz)
|
450 µg
|
|
|
|
|
Non-Linearity
|
±1 %
|
|
|
|
|
Transverse Sensitivity
|
<5 %
|
|
|
ENVIRONMENTAL
|
|
Overload Limit (Shock)
|
1,000 g pk
|
|
|
|
|
Temperature Range (Accelerometer)
|
-65 to 900 °F
|
|
|
|
|
Temperature Range (Charge Amplifier)
|
-60 to 250 °F
|
|
|
|
|
Temperature Response
|
See Graph
|
|
|
|
|
Base Strain Sensitivity
|
≤ 0.05 g/µε
|
|
|
ELECTRICAL
|
|
Settling Time (at 70 °F within 1% of bias)
|
≤ 1.0 sec
|
|
|
|
|
Discharge Time Constant
|
≥ .10 sec
|
|
|
|
|
Excitation Voltage
|
22 to 28 VDC
|
|
|
|
|
Constant Current Excitation
|
2.2 to 20 mA
|
|
|
|
|
Output Impedance
|
<1,000 Ohm
|
|
|
|
|
Output Bias Voltage
|
12 to 16 VDC
|
|
|
|
|
Spectral Noise (10 Hz)
|
11 µg/√Hz
|
|
|
|
|
Spectral Noise (100 Hz)
|
6 µg/√Hz
|
|
|
|
|
Spectral Noise (1 kHz)
|
4 µg/√Hz
|
|
|
|
|
Electrical Isolation
|
>108 Ohm
|
|
|
PHYSICAL
|
|
Size - Diameter
|
1.5 in
|
|
|
|
|
Size - Height
|
1.0 in
|
|
|
|
|
Weight (with cable)
|
9.5 oz
|
|
|
|
|
Mounting
|
Through Holes (3)
|
|
|
|
|
Sensing Geometry
|
Compression
|
|
|
|
|
Housing Material
|
Inconel
|
|
|
|
|
Sealing
|
Welded Hermetic
|
|
|
|
|
Electrical Connector
|
2-Pin MIL-C-5015
|
|
|
|
|
Electrical Connection Position
|
Side
|
|
|
|
|
Cable Length
|
10 ft
|
|
|
|
|
Cable Type
|
Integral Hardline
|
|
|
SUPPLIED ACCESSORIES:
|
| Model 081A99 Cap Screw (3) |
| Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to upper 5% frequency (1) |
|
OPTIONAL VERSIONS |
| EX - Hazardous Area Approval- contact factory for specific approvals |
|
|
All specifications are at room temperature unless otherwise specified.
|
| NOTES: |
| [1] |
1Hz = 60 cpm (cycles per minute). |
| [2] |
Conversion Factor 1g = 9.81 m/s². |
| [3] |
See PCB Declaration of Conformance PS023 or PS116 for details. |
| [4] |
The high frequency tolerance is accurate within ±10% of the specified frequency. |
| [5] |
Typical value. |
| [6] |
Zero-based, least-squares, straight line method. |
| [7] |
Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F, and G; Class III, Div. 1 |
| [8] |
Class I, Div. 2, Groups A, B, C, D |
| [9] |
Ex ia IIC T4. |
| [10] |
Ex nL IIC T1, II 3 G |
|
|
|
View Spec Sheet: 600A13_C.pdf
|
|