Swiveler® Industrial ICP® Accelerometer
Model 607A11
Low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, 10-ft integral cable & swiveler base
- Sensitivity: (±15%) 100 mV/g (10.2 mV/(m/s²))
- Frequency Range: (±3dB) 30 to 600000 cpm (0.5 to 10000 Hz)
- Measurement Range: ±50 g (±490 m/s²)
- Mounting: Stud
- Electrical Connector: Molded Integral Cable
|
PERFORMANCE
|
ENGLISH |
SI |
|
Sensitivity (±15 %)
|
100 mV/g
|
|
|
|
|
Measurement Range
|
±50 g
|
|
|
|
|
Frequency Range (±3 dB)
|
30 to 600,000 cpm
|
|
|
|
|
Resonant Frequency
|
1,500 kcpm
|
|
|
|
|
Broadband Resolution (1 to 10,000 Hz)
|
350 µg
|
|
|
|
|
Non-Linearity
|
±1 %
|
|
|
|
|
Transverse Sensitivity
|
≤ 7 %
|
|
|
ENVIRONMENTAL
|
|
Overload Limit (Shock)
|
5,000 g pk
|
|
|
|
|
Temperature Range
|
-65 to 250 °F
|
|
|
|
|
Temperature Response
|
See Graph
|
|
|
|
|
Enclosure Rating
|
IP68
|
|
|
ELECTRICAL
|
|
Settling Time (within 1% of bias)
|
≤ 2 sec
|
|
|
|
|
Discharge Time Constant
|
≥ 0.3 sec
|
|
|
|
|
Excitation Voltage
|
18 to 28 VDC
|
|
|
|
|
Constant Current Excitation
|
2 to 20 mA
|
|
|
|
|
Output Impedance
|
<150 ohm
|
|
|
|
|
Output Bias Voltage
|
8 to 12 VDC
|
|
|
|
|
Spectral Noise (10 Hz)
|
8 µg/√Hz
|
|
|
|
|
Spectral Noise (100 Hz)
|
5 µg/√Hz
|
|
|
|
|
Spectral Noise (1 kHz)
|
4 µg/√Hz
|
|
|
|
|
Electrical Isolation (Case)
|
>108 ohm
|
|
|
PHYSICAL
|
|
Size - Hex
|
9/16 in
|
|
|
|
|
Size - Height
|
0.97 in
|
|
|
|
|
Weight (without cable)
|
1.1 oz
|
|
|
|
|
Mounting
|
Stud
|
|
|
|
|
Mounting Thread
|
1/4-28 Male
|
|
|
|
|
Mounting Torque (stud)
|
7 to 8 ft-lb
|
|
|
|
|
Mounting Torque (hex nut)
|
2 to 5 ft-lb
|
|
|
|
|
Sensing Element
|
Ceramic
|
|
|
|
|
Sensing Geometry
|
Shear
|
|
|
|
|
Housing Material
|
Stainless Steel
|
|
|
|
|
Sealing
|
Welded Hermetic
|
|
|
|
|
Electrical Connector
|
Molded Integral Cable
|
|
|
|
|
Electrical Connection Position
|
Side
|
|
|
|
|
Cable Length
|
10 ft
|
|
|
|
|
Cable Type
|
Polyurethane
|
|
|
SUPPLIED ACCESSORIES:
|
| Model 080A156 Mounting Base (1) |
| Model ICS-2 NIST-traceable single-axis single-point amplitude response calibration at 6000 cpm (100 Hz) (1) |
|
OPTIONAL VERSIONS |
| EX - Hazardous Area Approval- contact factory for specific approvals |
|
|
|
Hazardous Area Approval
|
EEx nL IIC T4, -40°C≤Ta≤121°C, II 1 G
|
|
|
Hazardous Area Approval
|
Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
|
|
|
Hazardous Area Approval
|
Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
|
|
|
Hazardous Area Approval
|
Exia IIC T4, AExia IIC, T4
|
|
|
Hazardous Area Approval
|
EEx nL IIC T4, -40°C≤Ta≤121°C, II 3 G
|
|
|
|
|
Supplied Accessory : Model M080A159 Mounting stud, 1/2-20 to M6 x 1 (1) replaces Model 080A156
|
|
|
|
Temperature Output Range
|
36 to 250 °F
|
|
|
Temperature Scale Factor
|
5.56 mV/°F + 32
|
|
|
Electrical Connector
|
Molded Integral Cable
|
|
|
Electrical Connections (Red)
|
Acceleration Output
|
|
|
Electrical Connections
(Black)
|
Ground
|
|
|
Electrical Connections
(White)
|
Temperature Output
|
|
All specifications are at room temperature unless otherwise specified.
|
| NOTES: |
| [1] |
1/4-28 has no equivalent in S.I. units. |
| [2] |
1/8" hex Allen key required for English version, 4 mm hex Allen key required for Metric version. |
| [3] |
Conversion Factor 1g = 9.81 m/s². |
| [4] |
Measured with mounting stud. |
| [5] |
See PCB Declaration of Conformance PS023 or PS060 for details. |
| [6] |
Stud torque must exceed sensor hex nut torque to ensure proper dismantling. |
| [7] |
Twisted shielded pair. |
| [8] |
Typical. |
| [9] |
Zero-based, least-squares, straight line method. |
|
|
|
View Spec Sheet: 607A11_H.pdf
|
 |
Flat Surface Magnet
Model 080A120
|
|
 |
Curved Surface Magnet
Model 080A130
|
|
 |
Sensor Mounting Pad
Model 080A93
|
|
|