PERFORMANCE
|
ENGLISH |
SI |
|
Frequency Range (±3 dB)
|
180 to 60 kcpm
|
|
|
|
|
Hysteresis (% < Alarm Threshold)
|
3; 6; or 10 %
|
|
|
|
|
Residual Vibration Level (Reference)
|
Dependent or Independent
|
| Dependent or Independent |
[2] |
|
|
|
|
Residual Vibration Level (% Alarm Threshold)
|
1 to 40 %
|
|
|
|
|
MAVT (Sets Alarm Threshold to 2X actual vibration)
|
Enabled or Disabled
|
|
|
|
|
Transverse Sensitivity
|
<3 %
|
|
|
|
|
Power On Delay (±1 sec)
|
3 or 20 sec
|
|
|
|
|
Startup Delay (±1 sec or 1 min) (Time)
|
1 to 60 sec or 1 to 30 min
|
| 1 to 60 sec or 1 to 30 min |
[2] |
|
|
|
|
Startup Delay (x Alarm Threshold)
|
x2; x4; x8; Blocked
|
|
|
|
|
Startup Delay (Active)
|
Enabled or Disabled
|
|
|
|
|
Operational Delay (±1 sec)
|
1 to 60 sec
|
|
|
|
|
Relay
|
SPST, Form A or B MOSFET
|
|
|
|
|
Relay
|
24 to 240 V AC/DC, 500 mA
|
| 24 to 240 V AC/DC, 500 mA |
|
|
|
|
|
Relay
|
Latching / Non-Latching
|
| Latching / Non-Latching |
[2] |
|
|
|
|
Relay
|
Normally Open / Closed
|
| Normally Open / Closed |
[2] |
|
|
ENVIRONMENTAL
|
|
Temperature Range (Operating)
|
-40 to 185 °F
|
|
|
|
|
Temperature Range (Storage)
|
-40 to 257 °F
|
|
|
|
|
Overload Limit (Shock)
|
5,000 g pk
|
|
|
ELECTRICAL
|
|
Power Required
|
24 to 240 V DC/AC 50/60 Hz
|
| 24 to 240 V DC/AC 50/60 Hz |
|
|
|
|
|
Current Rating (Relay Closed)
|
500 mA
|
|
|
|
|
Leak Current (Relay Open)
|
≤ 1 mA
|
|
|
|
|
Electrical Isolation (Case)
|
>108 Ohm
|
|
|
PHYSICAL
|
|
Size - Hex
|
1.38 in
|
|
|
|
|
Size - Height
|
3.68 in
|
|
|
|
|
Weight
|
7.0 oz
|
|
|
|
|
Mounting Thread
|
1/4 NPT
|
|
|
|
|
Sensing Element (Internal)
|
Piezoelectric Accelerometer
|
| Piezoelectric Accelerometer |
|
|
|
|
|
Housing Material
|
Stainless Steel
|
|
|
|
|
Electrical Connector
|
Terminal Block
|
|
|
|
|
Electrical Connection Position
|
Top
|
|
|
|
|
Screw Terminal Wire Size
|
12-24 AWG
|
|
|
|
|
Conduit Housing Thread
|
1" NPT Female
|
|
|
OPTIONAL VERSIONS |
| EP - Explosion-proof certified conduit housing with 1" pipe thread |
|
|
| EX - Hazardous Area Approval- contact factory for specific approvals |
|
|
|
Hazardous Area Approval
|
Cl I, Div 2, Groups A, B, C, D; ExnA IIC T3, AExnA IIC T3
|
|