Temperature Output ICP® Accelerometers
 |
 |
 |
| Series TO601Ax1 |
 |
Low-noise, ceramic shear, top connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
50 µg resolution |
 |
16 to 600k cpm (0.32 to 10k Hz) frequency range [±3 dB] |
 |
Single point NIST traceable calibration at 6000 cpm (100 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO602Cx1 |
 |
Teardrop, ceramic shear, side connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
50 µg resolution |
 |
16 to 480k cpm (0.32 to 8k Hz) frequency range [±3 dB] |
 |
Single point NIST traceable calibration at 6000 cpm (100 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO603Cx1 |
 |
Low-noise, ceramic shear, top connection |
 |
High frequency |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
75 µg resolution |
 |
26 to 780k cpm (0.43 to 13k Hz) frequency range [±3 dB] |
 |
Single point NIST traceable calibration at 6000 cpm (100 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO622Ax1 |
 |
Low-noise, ceramic shear, top connection |
 |
High accuracy, high resolution |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
50 µg resolution |
 |
12 to 600k cpm (0.2 to 10k Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 300k cpm (10 to 5000 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO624Ax1 |
 |
Ring-shaped, quartz shear, side connection |
 |
High accuracy, stable performance |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
1000 µg resolution |
 |
48 to 600k cpm (0.8 to 10k Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 300k cpm (10 to 5000 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO625Bx1 |
 |
Low-noise, ceramic shear, side connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
50 µg resolution |
 |
12 to 630k cpm (0.2 to 10.5k Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 390k cpm (10 to 6500 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO625Bx2 |
 |
Low-noise, ceramic shear, side connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
500 mV/g acceleration sensitivity |
 |
15 µg resolution |
 |
12 to 360k cpm (0.2 to 6000 Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 120k cpm (10 to 2000 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO626Ax1 |
 |
Low-noise, ceramic shear, top connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
100 mV/g acceleration sensitivity |
 |
100 µg resolution |
 |
12 to 600k cpm (0.2 to 10k Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 300k cpm (10 to 5000 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO626Ax2 |
 |
Low-noise, ceramic shear, top connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
500 mV/g acceleration sensitivity |
 |
10 µg resolution |
 |
12 to 360k cpm (0.2 to 6000 Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 120k cpm (10 to 2000 Hz) |
 |
3-pin connector and two integral cable styles |
 |
 |
 |
| Series TO626Ax3 |
 |
Low-noise, ceramic shear, top connection |
 |
High resolution |
 |
10 mV/°C temperature sensitivity |
 |
1000 mV/g acceleration sensitivity |
 |
5 µg resolution |
 |
12 to 360k cpm (0.2 to 6000 Hz) frequency range [±3 dB] |
 |
Full NIST traceable calibration from 600 to 120k cpm (10 to 2000 Hz) |
 |
3-pin connector and two integral cable styles |
|
 |