Sign Up Now
FREE E-Newsletter

Search



ABOUT SSL CERTIFICATES

 

IN-LINE ICP TO 4-20 MA OUTPUT VELOCITY CONVERTER
Model 682A09     
 
Vibration transmitter (for use w/ICP® sensor), 4 to 20 mA output, 10 to 10k Hz
  • Output Range: 4 to 20 mA
  • Measurement Range: 0.0 to 1.0 in/sec pk (0.0 to 25.4 mm/s pk)
 
 
SpecificationsDrawingProduct ManualPicture 
PERFORMANCE ENGLISH SI
Input Signal (ICP Accelerometer) 100 mV/g
10.2 mV/(m/s2)
Frequency Response (-3dB ±2dB) 600 to 60,000 cpm
10 to 1,000 Hz
Measurement Range 0.0 to 1.0 in/sec pk
0.0 to 25.4 mm/s pk
Output Range 4 to 20 mA
4 to 20 mA
Broadband Resolution 0.01 in/sec pk
0.26 mm/s pk
ENVIRONMENTAL
Temperature Range -40 to 185 °F
-40 to 85 °C
Temperature Response (Sensitivity Deviation) ≤ 15 %
≤ 15 %
ELECTRICAL
Excitation Voltage 20 to 30 VDC
20 to 30 VDC
Electrical Isolation (Case) >108 Ohm
>108 Ohm
Settling Time (within 2% of value) <60 sec
<60 sec
Load Resistance 50 (Vs-20) Ohm
50 (Vs-20) Ohm
PHYSICAL
Size - Height 4.0 in
101.6 mm
Size - Diameter 0.621 in
15.8 mm
Weight 2.5 oz
71 gm
Housing Material Stainless Steel
Stainless Steel
Electrical Connector (#1) 2-Pin MIL-C-5015
2-Pin MIL-C-5015
Electrical Connection Position (#1) Sensor End
Sensor End
Electrical Connections (#1) (Pin A) AC IN Pos
AC IN Pos
Electrical Connections (#1) (Pin B) AC IN Neg
AC IN Neg
Electrical Connector (#2) 3-Pin MIL-C-5015
3-Pin MIL-C-5015
Electrical Connection Position (#2) Output End
Output End
Electrical Connections (#2) (Pin A) 4-20 mA Pos (+)
4-20 mA Pos (+)
Electrical Connections (#2) (Pin B) 4-20 mA Neg & AC OUT Neg
4-20 mA Neg & AC OUT Neg
Electrical Connections (#2) (Pin C) AC OUT Pos
AC OUT Pos
Sealing Welded Hermetic
Welded Hermetic

All specifications are at room temperature unless otherwise specified.